Dosage evaluation in brachytherapy coupled to boron neutron capturing therapy

Authors

  • Iara F. Chaves Departamento de Engenharia Nuclear. Universidade Federal de Minas Gerais (UFMG). Belo Horizonte (MG). Brasil
  • Tarcísio P.R. Campos Departamento de Engenharia Nuclear. Universidade Federal de Minas Gerais (UFMG). Belo Horizonte (MG). Brasil

DOI:

https://doi.org/10.32635/2176-9745.RBC.1996v42n3.3015

Keywords:

Radiotherapy, Brachytherapy, BNCT

Abstract

This paper introduces a new technique for radiotherapy based on the coupling of two distinct methods: the brachytherapy provided by discrete sources of neutrons and photons placed in intracavitary regions of patient, and the Boron Neutron Capture Therapy (BNCT). With the goal of studying the performance of the coupled treatment, computational evaluations are proposed to quantify the absorbed dosages. Analysis of possible neutrons sources, such as discret neutron sources, nuclear reator, linear acelerators - LINACs, and special devices for cold neutrons are presented in order to verify the feasibility of the instalation of neutron generators in hospitais.

Downloads

Download data is not yet available.

References

Laramore, G.E.; Wootton, P.; Livesey, J.C.; Wilbur, D.S.; Risler, R. et al. - Boron neutron capture therapy: a mechanism for achieving a concomitante tumor boost in fast neutron radiotherapy. Int J Radiat Oncol Biol Phys, 28: 1135-1142, 1994. DOI: https://doi.org/10.1016/0360-3016(94)90487-1

Barth, R.F.; Soloway, A.H.; Fairchild, R.G.; Brugger, R.M. - Boron neutron capture therapy for cancer. Cancer, 70: 2995-3004, 1992. DOI: https://doi.org/10.1002/1097-0142(19921215)70:12<2995::AID-CNCR2820701243>3.0.CO;2-#

Konijnenberg, M.W.; Raaijmakers, C.P.J.; Dewit, L.; Mijnheer, B.J.; Moss, R.L. et al. - Treatment planning of boron neutron capture therapy: Measurements and calculations. Radiat Protect Dosimet, 44: 443-446, 1992. DOI: https://doi.org/10.1093/rpd/44.1-4.443

Maruyama, Y. - Cf-252 new radioisotope for neutron therapy of bulky cervix, uterus, and outher cancers for developing nations. Physics of Radiotherapy and Imaging. Ed. Tata-McGraw Hill, NewDelhi, 1988, 151-179.

Maruyama, Y.; Van Nagell, J.R.; Yoneda, J.; Donaldson, E.; Gallion, H. et al. - Efficacy of brachytherapy with californium-252 nêutrons versus cesium-137 photons for eradication of bulky localized cervical cencer: single-institution study. JNCI, 80: 501-506, 1988. 5. DOI: https://doi.org/10.1093/jnci/80.7.501

Lennox, A.J. - Proton linacs for boron neutron capture therapy. International Particle Accelerator Conference, Washington, 1993,17-20. 6.

Liu, H.B.; Brugger, R.M.; Greenberg, D.D.; Rorer, D.C.; Hu, J.P. et al. - Enhancement of the epithermal nêutron beam used for boron neutron capture therapy. Int J Radiat Oncol Biol Phys,

: 1149-1156. 7.

Clark, D.D.; Hossain, T.Z. - A new instrument for activation analysis – the cold neutron irradiator. Am Nucl Soc, 68: 141-142, 1993.

Duderstadt, J.J.; Hamilton, L.J. - Nuclear Reactor Analysis. Ed. John Wiley & Sons, Inc. New York, 1976. 9.

Chaves, I.F.; Campos, T.P.R. – Modelo matemático e computacional para cálculo de doseem radioterapia interna por neutrons. XV Cilamce, 2: 1762-1771, 1994.

Published

2022-09-30

How to Cite

1.
Chaves IF, Campos TP. Dosage evaluation in brachytherapy coupled to boron neutron capturing therapy. Rev. Bras. Cancerol. [Internet]. 2022 Sep. 30 [cited 2024 Jul. 22];42(3):151-60. Available from: https://rbc.inca.gov.br/index.php/revista/article/view/3015

Issue

Section

ORIGINAL ARTICLE