Experiência do Centro Nacional de Transplante de Medula Óssea (CEMO) com uso de Cateteres tipo Hickman-Broviac

Authors

  • Eduardo D. Velasco Comissão de Controle de Infecção Hospitalar (CCIH). Rio de Janeiro (RJ), Brasil
  • Luis Fernando da Silva Bouzas Centro Nacional de Transplante de Medula Óssea (CEMO). Instituto Nacional de Câncer (INCA). Rio de Janeiro (RJ), Brasil
  • Daniel Tabak Centro Nacional de Transplante de Medula Óssea (CEMO). Instituto Nacional de Câncer (INCA). Rio de Janeiro (RJ), Brasil

DOI:

https://doi.org/10.32635/2176-9745.RBC.1987v33n1.3185

Keywords:

Central Venous Catheters, Catheter-Related Infections, Complications, Gram-Negative Organisms

Abstract

Forty-seven patients were admitted to National Center for Bone Marrow Transplantation — CEMO in Rio de Janeiro. Fifty-seven Hickman-Broviac catheters were inserted by venous access. The mean duration of catheterization was 38days (range, 1-209days) fora total of 3104 catheter-days. Twenty-eight catheters (49.1 %) were removed after catheter-related infections; infection rate was 42.1 % and mortality rate 4.2%. After modification to a weekly catheter care and heparinization program assisted by nursing staff, the initial infection rate (45.2%) dropped to 20 % for the last 15 catheters evaluated. Neutropenia was nota risk factor for the development of sepsis related to the catheter. Gram-negative organisms were the predominant etiologic agents isolated during the infectious episodes (52 %). Enterobacter sp. and S. epidermidis were isolated with equal frequency and represented 48% of the isolates. Six microorganisms (24 %) were resistant to antibioties used during the infectious episodes. Four gram-negative organisms were resistant to amikacin and two, gram-positive, were resistant to oxacillin.

Downloads

Download data is not yet available.

References

Broviac JW, Cole BS, Scribner BH - A silicone rubber catheter for prolonged parenteral alimentation. Surg Gynecol Obstet, 1973; 136: 602.

Hickman RO, Buckner CD, Clift RA, Sanders JE, Steward P, Thomas ED — A modified right atrial catheter for access to the venous system in marrow transplant recipients. Surg Gynecol Obstet, 1979; 148: 871.

Heimbach DM, Ivey TD — Technique for placement of permanent home hyperalimentation catheter. Surg Gynecol Obstet, 1976; 143: 635.

Riella MC, Scribner BH — Five years'experience with a right atrial cateter for prolonged parenteral nutrition at home. Surg Gynecol Obstet, 1976-143: 205.

Ivey MF, Adam SM, Hickman RO, Gibson DL — Right attrial indweiling catheter for patient requiring long term intravenous therapy. Am J Hosp Pharm, 1978; 35: 1525: DOI: https://doi.org/10.1093/ajhp/35.12.1525

Press OW, Ramsey PG, Larson EB, Fefer A, Hickman RO — Hickman cateter infections in patients with malignancies. Medicine, 1984; 63: 189. DOI: https://doi.org/10.1097/00005792-198407000-00001

Ryan Jr JA,Abel RM, Abbot WM et al — Catheter complications in total parenteral nutrition. A prospectivestudy of 200 consecutive patients. N EngI J Med, 1974; 290:757. DOI: https://doi.org/10.1056/NEJM197404042901401

Thomas JH, MacArthur RI, Pierce GE, Hermrec kAS — Hickman catheters: Indications and results. Am J Surg, 1980; 140: 791. DOI: https://doi.org/10.1016/0002-9610(80)90119-1

Thomas M — The use of the Hickman catheter in the management of patients with leukaemia and other malignancies. Br J Surg, 1979; 66: 673. DOI: https://doi.org/10.1002/bjs.1800660926

Lowder JN, Lazarus HM, Herzig RH — Bacteremias and fungemias in oncologic patients with central venous catheters: changing spectrum of infection. Arch Intern Med, 1982; 142: 1456. DOI: https://doi.org/10.1001/archinte.1982.00340210048012

Johnson PR, Decker MD, EdwardsKM, Schaffner W, Wright PF – Frequency of Broviac catheter infections in pediatric oncology patients. J Inf Dis, 1986; 154: 570. DOI: https://doi.org/10.1093/infdis/154.4.570

Stamm WE, Tompkins LS, Wagner KF et al — Infection due to Coryne bacterium sp. in marrow transplant patients. Ann Int Med, 1979; 91:167. DOI: https://doi.org/10.7326/0003-4819-91-2-167

Stiliman RM, Soliman F, Garcia L, SawyerPN — Etiologyof catheter — associated sepsis: Correlation with thrombogenicity. Arch Surg, 1977; 112: 1497. DOI: https://doi.org/10.1001/archsurg.1977.01370120087011

Winston DJ, Dudnick DV, Chaplin M, Ho WG, Gale RP, Martin WJ —Coagulase-negative staphylococcus bacteremia in patients receiving immunosupressive therapy. Arch Int Med, 1983; 143: 32. DOI: https://doi.org/10.1001/archinte.1983.00350010034007

Wade JC, Schimpff SWC, Newman KA, Wiernik PH — Staphylococcus epidermidis: an increasing cause of infection in patients with granulocytopenia. Ann Int Med, 1982; 97: 503. DOI: https://doi.org/10.7326/0003-4819-97-4-503

Peters G, Locei R, Pulverer G — Adherence and growthof coagulase-negative staphylococci on surfaces of intravenous catheters. J InfDis, 1982; 146: 479. DOI: https://doi.org/10.1093/infdis/146.4.479

Mc Couftie J, Douglas U — Relationship between cell surface composition of Candida albicans and adherence to acrylic after growth on different carbon sources. Infect Immunol, 1981; 32: 1234. DOI: https://doi.org/10.1128/iai.32.3.1234-1241.1981

Published

2023-08-04

How to Cite

1.
Velasco ED, Bouzas LF da S, Tabak D. Experiência do Centro Nacional de Transplante de Medula Óssea (CEMO) com uso de Cateteres tipo Hickman-Broviac. Rev. Bras. Cancerol. [Internet]. 2023 Aug. 4 [cited 2024 Jul. 22];33(1):23-8. Available from: https://rbc.inca.gov.br/index.php/revista/article/view/3185

Issue

Section

ORIGINAL ARTICLE

Most read articles by the same author(s)